- Turbovac 800 Manual And Accessories
- Turbovac 800 Filter
- Everstar Turbovac 800 Manual
- How To Empty Turbovac 800
Turbovac 800 Dual Action ManualTurbovac 800 Dual Action ManualTurbovac 800 parts plastic hoses and flex hose - Vacuums question. Here is the Instruction or User Manual for the 8920, 9200, 9300, 9400, series machines.The family was given the new name called Benton Sans. A face was discharged for open. We have a Everstar Turbo Vac. 180 and so far its been wonderful. All of a sudden it became really loud and spitted out the debree. Took it to a vac. Repair shop and he wouldnt even look at it! Any suggestions? I found my Everstar near a neighbor's trash.
Omcan Turbovac 16.90 inch Vacuum Packaging Machine Description. Omcan offers a wide selection of vacuum packaging machines, ideal for a variety of applications. Vacuum packed products lose less weight and when kept at the correct temperature, improves shelf life. The chamber system provides faster vacuuming times.
EverStar air conditioner is the silent leader when it comes to portable air conditioning systems meant for home or small office use. It’s not the biggest name in the market, but has been providing quality, efficient, durable and very affordable portable air conditioner units that are considered must haves especially during the short but hot summer season. Ask an existing unit owner and be surprised how these small air conditioners have lived up to their expectations.
How a Portable Air Conditioner Works
As their name suggests, this type of air conditioner needs no installation in the window, wall, ceiling etc and can be carried and placed anywhere or any room where air cooling is needed. They work almost in the same way with conventional air conditioners. And the only difference is on the aspect of ventilation, exhaust or draining. Portable ACs feature vent hoses or pipes that shall be extended out of the room.
A unit can either have one or two vent hoses depending on how the unit gets rid of the warm or humid air. There are fully evaporative models wherein the water which is the by-product of condensation gets fully evaporated and no draining is required. There are models that feature hoses and drain the water automatically through gravity. While the most basic models have interior water basins and they should manually be emptied.
Unique and Great Features of EverStar Air conditioner
What do you get from your EverStar portable air conditioner? The following beneficial features:
- A true air conditioning workhorse. Majority of the old Everstar air conditioning units that have been in use for decades are still running and efficient until today. There are even reviews that a grandmother’s Everstar has been inherited by his grandchild and is still making an efficient air freeze.
- Air conditioner and humidifier in one. The main problem with hot weather is too much air humidity. But with the portable AC units offered by the brand, you will no longer need a separate dehumidifier machine or unit because this brand offers these functionalities as one. For light or minimal cooling, Everstar’s humidifier mode, can already handle the job. For a more chilling environment, then that’s the time to turn the AC mode on.
- Fully evaporative models. With an EverStar AC unit, there is no longer a need to manually drain or remove water created by condensation or humidity removal. The models offered by the brand are fully evaporative and the water vapor is exhausted out in the air.
- 24 Hour On/Off timer. For energy savings and flexibility, the Everstar air conditioner has a timer that can be set anytime of the day.
- Affordable air conditioning unit. Simply, you get that cool or frigid air at the very least cost.
- Really built to cool down a room. Read all the reviews for this brand of air conditioner and all will agree that these units give the best cooling efficiency. At times, even better than conventional air conditioning units.
EverStar Portable Air Conditioner Models
There are currently four specific models or types of portable AC the brand offer. And they are differentiated by cooling capacity.
EverStar MPA-08CR 8000 BTU air conditioner
The smallest or lightest in fleet is the MPA-08CR which has a cooling capacity of 8000 BTUs which is capable of cooling a room up to 340 square feet. It has a very efficient energy star rating of 9.4 and extra features include 2-way air deflection, variable fan speeds and cooling options.
Turbovac 800 Manual And Accessories
EverStar MPN1-095CR 9500 BTU air conditioner
Next on the list is the MPN1-095CR with a 9500 cooling capacity fit for rooms up to 420 square feet. Other features include semi-automatic draining and a 4-way air deflection.
EverStar MPK-10CR 10000 BTU air conditioner
Turbovac 800 Filter
The MPK-10CR is the newer generation of portable air conditioner offered by the brand. It offers a cooling power of 10000 BTUs capable of cooling spaces that are up to 450 square feet. Extra features include; fully evaporative condensation, remote controlled settings, an ionizer, timer, high-tech air filters plus casters or rollers for easy handling.
EverStar MPN1-11CR 11000 BTU air conditioner
The largest EverStar air conditioner is the MPN1-11CR model has the same advanced features as the MPK-10CR plus a myriad of others. It has a cooling capacity of 11000 BTUs fit for spaces of up to 500 to 550 square feet.
Everstar Portable Air Conditioner Error Codes;
Error Codes | Problem-Solution |
---|---|
P1 | The LCD window will shows 'P1' and the Water Full indicator will flash every 0.5 seconds. |
P2 | Compressor does not work and the digital display area shows “ P2 '. The bottom tray is full |
E1 | The cooting indicator light flashes at 1H: and the digital display area shows “E1 '. The room temperature Sensor is off or shon-circuit. |
E2 | The FAN indicator light flashes at 1H: and the digital display area shows “ E2 '. The Evaporator Temperature Sensor is off or short-circuit. |
E3 | The Dehumidifying indicator light flashes at 1H: and the digital display area shows 'E3'. The Condenser Temperature Sensor is off or short-circuit. |
Troubleshooting
Troubles: Unit does not Start when Pressing onloff Button
Possible Causes:
- Wateriull indicator blinks, water tank is full.
- Room temperature is higher than the set temperature.
- Room temperature is lower than the set temperature.
Suggest Remedies:
- Dump the water in the water tank.
- Reset the temperature.
- Reset the temperature.
Troubles: Not cool enough
Possible Causes:
- The windows or doors in the room are not closed.
- There are heat sources inside the room.
- Exhaust air duct is not connected or blocked.
- Temperature setting is too high.
- Air filter is blocked by dust.
Suggest Remedies:
- Make sure all the windows and doors are closed.
- Remove the heat sources it possible.
- Connect the duct and make sure it can function properly.
- Decrease the set temperature.
- Clean the air filter.
Troubles: Noisy or vibration
Everstar Turbovac 800 Manual
Possible Causes: The ground is not level or not flat enough.
Suggest Remedies: Place the unit on a flat. level ground if possible.
Troubles: Gurgling sound
Possible Causes: The sound comes from the flowing of the refrigerant inside the air conditioner.
Suggest Remedies: It is normal.
How To Empty Turbovac 800
How to Fix P1 Error?
This unit is equipped with a fail-safe switch mechanism which prevents the unit from condensing water in the event the water tank is accidentally displaced, and / or FULL with water. If this situation occurs, the LED window shows “P1” and the WATER FULL indicator light will flash red continuously until the water tank is correctly positioned and/or emptied. Condensed water will be accumulated in the water tank. When the tank is full, the LED window will show “P1” and the Water Full indicator light start flashing. At this time the air cooling process will immediately stop. However, the fan motor will continue to operate (this is normal). Carefully remove the water tank from the cabinet and dispose of the water. Replace the water tank back to it’s original position (in cabinet) and the air cooling process will automatically resume. It may take 3-5 minutes for the compressor to re-start. This is normal.